Abstracts

Pericardial effusions and cardiac tamponade associated with neonatal long lines – are they really a problem?

Presented at the Neonatal Society 2001 Summer Meeting.

Beardsall K, White DK, Kelsall AWR.

Neonatal Intensive Care Unit, Rosie Hospital, Addenbrooke’s Hospital, Cambridge. CB2 2QQ

Introduction: Percutaneous long lines (PLL) are now routinely used in neonatal intensive care units (NICU) and provide a safe and secure route of vascular access for the administration of parental nutrition. A number of different complications have been reported with pericardial effusion/cardiac tamponade being the most serious and potentially fatal. Parents have recently been made aware of this complication following media coverage. The neonatal literature contains only a few case reports. There are no studies that investigate the incidence of pericardial effusion/cardiac tamponade associated with the use of PLLs.

Methods: We have conducted a retrospective survey to determine the incidence of this problem over the last 5 years. A questionnaire was sent to the lead neonatal/paediatric clinician in all United Kingdom hospitals providing neonatal/special care.

Results: 243 questionnaires were sent and 173 returned (71%). 149 (86%) of the responding units routinely inserted PLLs. Of these, 103 (69%) inserted <50 PLLs and only 21 (14%) inserted > 100 PLLs per year. From the replies, we estimate that approximately 8,000 PLLs are inserted per annum. All units check the position of PLLs by x-ray but only 41 (27%) routinely use intravenous contrast. Eighty-six (58%) aimed to position the PLL in the vena cavae with the line tip outside the heart. Sixty-three (42%) were content with the PLL tip in the right atrium. Over the 5-year study period, 63 cases of pericardial effusion/cardiac tamponade were identified. Information was available in 62 cases. Thirty-four (55%) infants survived. The condition was suspected in 42 cases (68%) and confirmed by echocardiography in 28 (45%). Pericardial taps were attempted in 32 (52%). Of the 28 infants who died, diagnosis was made at post mortem in 20. Over the study period we estimate that 1.6 pericardial effusions/cardiac tamponades will occur for every 1,000 lines inserted, with a fatality rate of 0.7 per 1,000 PLLs inserted.

Conclusions: There is wide variation in the use of PLLs in neonates in the UK. The incidence of pericardial effusion/cardiac tamponade is very low. A significant proportion are diagnosed after death. Our figures almost certainly underestimate the incidence as it is a retrospective study. In addition, further cases may have been missed if post mortems were not performed. We aim to conduct a prospective study to determine the extent of the problem.

References
1. Beattie PG, Kuschel CA and Harding JE. Pericardial effusion complicating a percutaneous central venous line in a neonate. Acta Paediatr 1993;82:105-7.
2. Harms K, Herting E, Kruger T, Compagnone D and Speer CP. Percutaneous silastic catheters in newborn and premature infants. A report of experiences with 497 catheters in 5 years. Monatsschr Kinderheilkd 1992; 140(8):464-71.
3.Khilnani P, Toce S and Reddy R. Mechanical complications from very small percutaneous central venous silastic catheters. Critical Care Medicine 1990;18(12):1477-1478.

More to explorer

Summer Meeting 2026

24th & 25th June 2026 Hybrid event: Virtual meeting or in person at University of Newcastle Register Here Submit Abstract Submission deadline

Spring Meeting 2026

19th March 2026 Hybrid event: Both online and in-person meeting at the Royal College of Obstetricians and Gynaecologists (RCOG), London 9:00-17:45 Register

Autumn Meeting 2025

  The Neonatal Society AGM will take place on the same day during a break in the sessions.  Friday 21st November 2025

Search by category
Scroll to Top

We use cookies to improve your experience on our website. By browsing this website, you agree to our use of cookies.